FINAL CERTIFICATE OF OCCUPANCY REQUIREMENTS
CHECK OFF LIST
House number attached
Outside Steps & Porch
1) 3 Steps need railings 36” (One side)
2) Above 30” need balusters every 4”
Outside Receptacle GFI
Garage
1) Firewall 5/8” Firecode sheetrock & Tape
2) Fire Doors self closing
3) Door opener safety stops
4) Floor at least 4” drop from living area
Dishwasher Vacuum Break
Kitchen sink operational
Outlets covered
Kitchen outlets GFI
Outlet in island
Appliance wires in Boxes if not attached
One bathroom operational with GFI outlets
Patio doors blocked or opening on finished patio
Egress doors & windows proper size
Joist hangers or ledger steps
Smoke detectors all floors and in each sleeping area
Bridging
Stairway rails & Balusters main & basement
Lally column plates nailed
Chimney
1) Fire stops/ Aluminum not acceptable
2) Clean Outs 16” above basement floor
3) Clearance from combustible materials 18” min. (cleanout) 2” around masonry
4) Power vent clearance 4’ from any window or door
Breaker Box
1) Cold water ground
2) Breakers labeled
Oil Tank
1) Vent installed
2) 12” legs only
3) Oil line protected and secured
4) Filter
|